OMNI Programming

1. Open the latest PC access file

2. Make sure you have the Macro IDs.

3. Communication (tab) > connect > network

4. Communication (tab) > read from controller

5. Go to Messages

6. Select any message number and edit according to the below image

Example: Burglar Alarm

168 - Macro ID that was created in RTI

7. Go to automation tab*

8. Save and Write to Controller

* For more information in creating alarm automation, click on the tabs below. 

  1. Create add automation block
  2. Select add trigger
  3. Select trigger type (Alarm)
  4. Select alarm type (Burglary)
  5. Select area ( any)
  6. press ok.

a. Select action (THEN) >
b. Select action type (Message) >
c. Select message command (Send) >
d. Select message (Burglar email)
e. Select serial port (1).

  1. Create add automation block
  2. Select add trigger
  3. Select trigger type (Alarm)
  4. Select alarm type (Fire)
  5. select area ( any)
  6. press ok.
    a. Select action (THEN)
    b. Select action type (Message)
    c. Select message command (Send)
    d. Select message (Fire email)
    e. Select serial port (1).
  1. Create add automation block
  2. Select add trigger
  3. Select trigger type (Security)
  4. Select alarm type (Away)
  5. Select area (any area)
  6. Select codes (All codes)
  7. Select when activated (End of exit delay)
  8. Select press ok.
    a. Select action (THEN)
    b. Select action type (Message)
    c. Select message command (Send)
    d. Select message (Armed email)
  1. Create add automation block
  2. Select add trigger
  3. Select trigger type (Security)
  4. Select alarm type (Off)
  5. Select area (Any area)
  6. Select codes (All codes)
  7. Select press ok.
    a. Select action (THEN)
    b. Select action type (Message)
    c. Select message command (Send)
    d. Select message (Disarmed email)
    e. Select serial port(1)
After completing write to controller make sure to test it.
  1. Select communication tab  
  2. Select send command
  3. Select action type(Message)
  4. Select message command(Send)
  5. Select message (Burglar email)
  6. Select serial port (1)